Inconsistent specification of X_VERSIONED_OBJECT.owner_id

Description

The EXTRACT spec defines X_VERSIONED_OBJECT.owner_id as OBJECT_REF in the UML in Figure 6 but LOCATABLE_REF in the table in section 4.3.14. This table describes owner_id as "from original VERSIONED_OBJECT which identified the source EHR", the VERSIONED_OBJECT.owner_id is OBJECT_REF. The XML Schema uses OBJECT_REF.

Environment

None

Activity

Show:
Thomas Beale
June 8, 2015, 10:09 PM

The error reported by Heath is correct, and should be corrected in the specification.

Reporter

Heath Frankel

Labels

None

Affects versions

Priority

Minor
Configure